![Sybase Sql Anywhere Studio 9.0.2 Sybase Sql Anywhere Studio 9.0.2](https://www.omnis.net/developers/resources/technotes/images/tnsq0021_3.gif)
This is fixed, the database will now shut down correctly.
Sybase Sql Anywhere Studio 9.0.2 free#
END), an error was correctly given, however, an assertion would result when the database was stopped, (Assertion 104301 - Attempt to free a user descriptor with non-zero reference count). If a stored procedure which returned a result set was called from within an atomic compound statement (i.e. This has been fixed so that the server will correctly autostop. the main thread did not wait for the child thread to complete before ending the child thread did a disconnect as part of shutting down the main thread of the application signaled a child thread to shut down the server was autostarted by a multithreaded application Note, this scenario could have occurred in a multithreaded application if all of the following conditions were true: Pressing shutdown would have stopped the server though. In these cases, the server icon and window would still have been active, and the database would have been stopped, but no connections could have been made to the server. If a client application terminated while the last connection to the server was in the process of being disconnected, the server may not have autostopped when it should. This is still the case, and there is no workaround. NOTE: 6.x versions of dbconsol on all platforms fail to connect to servers after version 9.0.0 1223. Foreign key names were not being output in the ALTER TABLE ADD FOREIGN KEY statement.Īttempting to run m and connect to a server would have caused an abend. A uniqueidentifier column that defaulted to NEWID was incorrectly generated as new_uuid.ģ. UltraLite tables with TIME columns that defaulted to CURRENT TIME, or a specific date, was incorrectly generated.Ģ. The following changes have been made to generate correct values and foreign names in the output SQL stream:ġ. This has been fixed - the environment variables listed above will now be useed when creating the file.Ĭreating the file ahead of time to match the intended usage works odbc.ini file, but if no such file was found, it was always created in the user's home directory. On Unix systems, the Data Source utility dbdsn uses the ODBCINI, ODBC_INI, ODBCHOME, and HOME environment variables when trying to find the. Predicates of the form "constant IS NULL" may have been incorrectly evaluated as FALSE, for special constants such as "CURRENT REMOTE USER" or "CURRENT PUBLISHER". When run on Unix systems, the server could have crashed when a non-DBA user was connected, if auditing was enabled. Ultralite Dynamic SQL would have failed to prepare a CREATE TABLE statement when one of the columns contained a partition size with a global autoincrement default.Ĭol_a int default global autoincrement( 10000 ) This address is now ignored when creating the list for LDAP.
Sybase Sql Anywhere Studio 9.0.2 windows#
The list of IP addresses from these versions of Windows includes 0 (i.e.
![Sybase Sql Anywhere Studio 9.0.2 Sybase Sql Anywhere Studio 9.0.2](https://cdn.slidesharecdn.com/ss_thumbnails/sql-anywhere-1215725050472399-9-thumbnail-4.jpg)
On systems rinning Windows 95, 98, or ME, with the LDAP feature in use, the database server would have registered the invalid IP address "0.0.0.0" in LDAP, as well as the real machine's address. Now, if an unsupported column type is encountered, the wizard restricts the selection of only those columns that are supported. This has been fixed.Īttempting to use the Proxy Table wizard to create a proxy table for a remote table that contained a column type not supported by Adaptive Server Anywhere, would have caused Sybase Central to display an internal error. If the procedure contained OUTPUT parameters, the output variables would not be set when the procedure returned, or a "variable not found" error would have been reported. If the EXECUTE IMMEDIATE statement was used to perform a CALL containing variables as procedure arguments, the parameter values would have failed to be passed to the called procedure. Now, the MobiLink server will display an error, and abort the synchronization, if the length of the column value is greater than the column width defined in the remote database. This may have caused the ASA client to crash. If the consolidated and remote databases had different collations, the MobiLink Synchronization server may not have respected the column width defined in the remote database for columns defined with char or varchar datatypes. Attempting to use a view that referenced a proxy table, and contained a subselect which used an aggregate function, would have failed with the error "invalid use of an aggregate function".